– 8 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
8. SELF DIAGNOSTIC FUNCTION
1) Press “9” button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among IC’s are executed properly.
2) During diagnosis, the following displays are shown.
SELF CHECK
NO. 23 * * * * * *
POWER : 000
BUS LINE : OK
BUS CONT : OK
BLOCK : MAIN SUB
SET ID : 01
EEP VER : 02
OPT1 : 05 OPT2 : 70
*
The item marked with are not usable to display in the SELF DIAGNOSTIC FUNCTION for some model.
Part number of microprocessor (QA01)
Operation number of protection circuit (current limiter) . . . . 000 is normal.
BUS line check OK ................... Normal
NG ................... SCL-GND
or SAD-GND short circuit
BUS line ACK (acknowledge) check
OK ..................... Normal
Display of Location Number . . . . NG
(Display example)
QA02 NG, H001 NG, Q501 NG etc.
Note: The indication of failure place is only one place though failure places are plural. When
repair of a failure place finishes, the next failure place is indicated. (The order of priority of
indication is left side.)
Sync. signal check Green display ..... Normal
Cyan display ...... No check
Red display ........ NG
SET ID : 01 SET ID
EEP VER : 02 E2P version
OPT1 : 05 OPT2 : 70 OPT DATA