– 13 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
[SBY]
[SRY]
[COLS]
SECAM
B-Y Black
level
SECAM
R-Y Black
level
Sub-color
Center
SECAM
PICTURE MODE-1
Screen size: WIDE
SECAM Color bar
SECAM Color bar
SECAM Color bar
TP01
TP02
TP46B
쩸 Vary [SBY] so that the level of black and
white signal areas will be aligned with that
of BLK.
쩸 Vary [SRY] so that the level of black and
white signal areas will be aligned with that
of H. BLK.
쩸 Adjust the amplitude of B-Y.
(Apply Y mute at the time of adjustment)
0 ± 10 mV
0 ± 10 mV
1.6 ± 0.1 Vo-p
(Pedestal to Peak)
Items Names
Settings
Input signals Measuring points Adjusting methods Adjusting standards
(User control)