Subject:
Product Engineering Specification
Part No.:
BK.01191.203
Rev.: 4
Doc. No.: 201-C005
Project Code:
BK.01191.001
Page 10 of 15
Model Name:
B191-203
Form No.:A-01-001-09(111107) 保存期限:最新狀態 保存單位:eGRNSystem
過期處置:背面紙
Release Notice
6. Environmental
6.1 Temperature.
Operating
The power supply is capable to operate from -10 to 60℃.
6.2 Humidity
Operating
The power supply is capable to operate from 5 to 90% RH.
Non- Operating
The power supply is capable to be stored from 5 to 90% RH (non-condensing).
6.3 Dielectric Withstand Voltage (HI-POT)
PA/OQC/Product Line:
Between AC input and secondary applied AC 3KV test time 1 minute, cut off current shall be
less than 6mA for design sample
AC 3.5KV/6mA test time 3sec. for mass production
6.4 MTBF-Calculation
50K hours min.
MTBF Calculation compliant with MIL-217F.
6.5 Components de-rating
All components de-rating should be meet DARFON’s components de-rating criteria.
6.6 Open/Short test
All components should to do Open/Short test.
6.7 Acoustics
<30dB distance 10cm (with system) at ac max./min. voltage, <24dB at standby mode.
6.8 EMS
Products Safety Approvals
The power supply should be meet safety regulation as following: UL 60065, IEC/EN 60065.
Test item Test Specification IEC Standard
ESD Air 8KV, Contact 4KV 61000-4-2
SURGE 1KV(L-N) & 2KV(L/N-PE)/1.2~50μsec 61000-4-5
EFT 2KV on AC power line 61000-4-4
DIPS 0% 250Cy, 40% 5Cy,70% 5Cy 61000-4-11