(Refer to setting data of Main board.)
Adjusting the Data
Pressing of VOLUME +/- button will change the value of data in the range from 00H to
FFH. The variable range depends on the adjusting item.
Setting Panel Option Data
Panel option data is subject to OPT4 and OPT5.
Enter to service mode and select menu of OPT4 or OPT5 by pressing P or P during
display of adjustment menu. After selecting OPT4 or OPT5, press + or - to set OPT4
or OPT5 value as table below.
Panel option data
OPT4
Ex. OPT4 value 0x05 indicates that panel vendor is AUO AMVA.
Series Model name Panel vendor OPT4 value OPT5 value
AV500P EU 32AV500P LPL 0x01 0x05
IPS 0x07 0x05
37AV500P LPL 0x01 0x06
IPS 0x07 0x06
42AV500P LPL 0x01 0x07
OPT4
D7
(bit7)
D6
(bit6)
D5
(bit5)
D4
(bit4)
D3
(bit3)
D2
(bit2)
D1
(bit1)
D0
(bit0)
Panel vendor LPL - - - - 0 0 0 1
SHP - - - - 0 0 1 0