4 SETUP AND PREPARATION BEFORE OPERATION
POINT
(1) Set the offset and gain values in the actual usage state.
(2) The offset and gain values are stored on E
2
PROM in the AJ65VBTCU-
68ADVN/ADIN and are not cleared at power-off.
(3) Make offset/gain setting within the range indicated in POINT of Section 3.3.1
and Section 3.3.2. If setting is made outside this range, the maximum
resolution/accuracy may not fall within the performance specifications range.
(4) When making offset/gain setting (in the test mode), set any of the following test
modes with the mode select switch.
AJ65VBTCU-68ADVN (Ver. 1 remote device station): 1, 2
AJ65VBTCU-68ADVN (Ver. 2 remote device station): 4, 5
AJ65VBTCU-68ADIN (Ver. 1 remote device station): 1
AJ65VBTCU-68ADIN (Ver. 2 remote device station): 4
The user range settings 1 selected with the mode select switch set to 1 and 4
are the same. The setting of the user range setting 1 can be changed by setting
the mode select switch to either 1 or 4. This also applies to the user range
settings 2 selected with the mode select switch set to 2 and 5.
If the switch has been set to any unusable number, an error occurs and the
"RUN" LED flickers at intervals of 0.1s.
(5) When the grounding indicated in Section 4.8.2 *5 is changed (not performed
perform, or performed to removed), repeat the offset/gain setting from the start.