E6-1
6. SET UP PROCEDURE
ENGLISH VERSION EO1-33014
6.1 Requirements for Operation
6. SET UP PROCEDURE
6.1 Requirements for Operation
This machine has the following requirements:
The host computer must have a serial port.
To communicate with host, either an exclusive RS-232C cable is required.
RS-232C cable 9 pins
To print a label format, create the complete program using the interface/communication manual.
Interface Cables
NOTE: This printer requires an exclusive printer cable, shielded, 1.5 m maximum length. When
purchasing it, please contact your authorized TOSHIBA TEC representative.
To prevent radiation and reception of electrical noise, the interface cables must meet the following
requirements:
Fully shielded and fitted with metal or metalised connector housings.
Kept as short as possible.
RS-232C Cable description
The serial data cable used to connect the printer to the host computer should be the following type:
PIN No.
1
3
2
7
8
4
6
9
5
Signal
CD
TXD
RXD
RTS
CTS
DTR
DSR
CI
GND
DB-9S
Connector to PC
DHF-RAA10-213ND
Connector to Printer
PIN No.
1
2
3
4
5
6
7
8
9
10
Signal
P5V
P5V
TXD
RXD
RTS
CTS
TEST
SG1
SG1
SG2
Fig. 6-1