CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
B-EP Series
5-36
Mm: Type of check digits to be attached
(Omissible. If omitted, no check digit is drawn.)
m: Type of check digit
0: Modulus 10 (draws data and check digit.)
1: Modulus 43 (draws data and check digit.)
2: DBP Modulus 10 (Draws check digit only.)
* Reserved in the case of the compatible mode for the B-SP series
noooooooooo: Increment and decrement
(Omissible. If omitted, increment/decrement is not performed.)
n: Designates whether to increment or decrement.
+: Increment
-: Decrement
oooooooooo: Skip value
0000000000 to 9999999999
Zpp: Zero suppress (Omissible. If omitted, zero suppression is not performed.)
pp: No. of digits after zero suppression
00 to 20
* Reserved in the case of the compatible mode for the B-SP series
Pq: Alignment (Omissible. If omitted, the alignment is set to the left.)
q: Designates the character position
1: Left
2: Center
3: Right
4aaaa: Justification
aaaa: Character string in the X direction
0050 to 1040 (in 0.1 mm units)
5aaaabbbcc: Automatic line feed
aaaa: Character string in the X direction
0050 to 1040 (in 0.1 mm units)
bbb: Line feed spacing
010 to 500 (in 0.1 mm units)
cc: No. of lines
01 to 99
rrr ------ rrr: Data string to be printed (Omissible)
Max. 255 digits
ss
1
, ss
2
, ss
3
------ , ss
20
: Link field No. (Omissible)
01 to 99 (1 to 99 can also be used.)
Up to 20 fields can be designated using commas.