EasyManua.ls Logo

Toshiba B-EP Series - Page 45

Toshiba B-EP Series
228 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 36 -
No.
LCD Message
LED
Indication
Printer Status
Recoverable
by the
[PAUSE] key
Acceptance
of Status
Request
and
(English)
Status
Yes/No
Reset
Commands
Yes/No
20
SYSTEM ERROR
U
When the following abnormal operations
are performed, a system error occurs:
(a) Command fetch from an odd address
(b) Access to word data at an odd address
(c) Access to long-word data at an odd
address
(d) Access to the area of 80000000H to
FFFFFFFFH in the logic space in user
mode.
(e) An undefined instruction in an area
other than a delay slot was decoded.
(f) An undefined instruction in a delay slot
was decoded.
(g) An instruction to rewrite a delay slot
was decoded.
No No
21
WAITING (BATT.)
{
The battery protection function is in
operation.
– Yes
22
WAITING (HEAD)
{
The head protection function is in
operation.
– Yes
23
WAITING (MOTOR)
{
The motor protection function is in
operation.
– Yes
24
BT INIT ERROR
{
Initialization of Bluetooth failed.
No Yes
25
BT SETTING ERROR
{
There is/are error(s) in the Bluetooth
setting.
No Yes
26
CHARGE ERROR $
{
An error occurred during battery charge.
No Yes
27
Ir PACKET ERROR
U
A block number error occurred when using
TEC Protocol.
Yes Yes
28 Display of error
command
(See NOTE 1.)
U
A command error occurred in analyzing a
command.
Yes Yes
* No.11: The LCD display changes from “SAVING #### &&&&” to “ON LINE” in B-SP series
compatibility mode.

Table of Contents