- 169 -
6.3.29 VERSION INFORMATION ACQUIRE COMMAND [ESC] WV
Function Sends information such as the program version of the printer.
Format [ESC] WV [LF] [NUL]
Explanation (1) The format of the program version data (total 27 bytes of data) to be returned to
the host is as follows.
SOH 01H
STX 02H
“0” 30H
“4” 34H
“A” 41H
“P” 50H
Creation date “R” 52H
“2” 32H
“0” 30H
“0” 30H
“3” 33H
“B” 42H
“-“ 2DH
“E” 45H
Model “V” 56H
“4” 34H
“D” 44H
SP 20H
“V” 56H
“1” 31H
Version “.” 2EH
“0” 30H
“A” 41H
ETX 03H
EOT 04H
CR 0DH
LF 0AH
(2) This command is one of the types of commands that is processed as it is received.
Processing takes place starting from the ones received first. Until the process of
the command previously sent is completed, the next command is not processed.
Therefore, if the printer is not in the idle state when this command is sent, the
program version data may not be returned immediately.
Notes (1) This command is effective only for the serial interface (RS-232C).
This command is not supported for a parallel interface (Centronics), since
transmission cannot be performed in the parallel interface.
Creation date of program:
9 bytes of data indicated in order of Day-
Month-Year
Program version:
5 bytes of data: Vx.xx
Revision
Version
Model:
7 bytes of ASCII code indicating model