10. RFID ANALYZE TOOL EO18-33027
10.4 Operating Procedure
10- 19
6. Perform a write test or read test.
Write test
Click on the Write Testbutton to start a write test.
During the write test, total number of successful write and total number of write performed are shown in
the status bar. In the text box above the status bar, status data sent from the RFID module is displayed.
When the test is completed, all test results are shown in the Resultsbox.
Read test
Click on the “Read Test” button to start a read test.
During the read test, total number of successful read and total number of read performed are shown in
the status bar. In the text box above the status bar, status data sent from the RFID module is displayed.
When the test is completed, all test results are shown in the “Results” box.
Status bar
Text box
Results box
Write Test
button
Status
Data
All read or write
test results
Read Test
button
Write/Read Results Box (When U2 is selected.)
Power Level
Feed amount
Number of times data read succeeded/Total
number of read performed
EPC Code (displayed only when a read test is
performed. )
<AGC L
evel 00> AGC 1
st
data: Rank 00 level
<AGC Level 00> AGC 2
nd
data: Rank 00 level
<AGC Level 00> AGC 3
rd
data: Rank 00 level
<AGC Level 00> AGC 4
th
data: Rank 00 level
<AGC Level 00> AGC 5
th
data: Rank 00 level
Example