4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-33027
(Revision Date: Sept. 5, 2014)
4.10 UHF RFID KIT (B-EX700-RFID-U4-US/EU/CN-R)
4-67
4.10.9 OTHER
(1) TAG CHECK
OFF Error tag detection is not performed. Though a tag is read before writing data on it, data is
always written on the tag whatever data is set as the header data.
ON (ID) Error tag detection is performed. A tag (EPC area for GEN2 tags) is read before writing
data on it and data is written on the tag only when the header data is A5A5”.
ON (ACCESS PASSWORD) Error tag detection is performed only for Gen2 tags. The access
password area of a tag is read before writing data on it. Only when
the data read matches the access password setting data, the data is
written on the tag.
To prevent unauthorized changes of the setting, a password to protect the error tag detection setting
can be programmed.
1
When the TAG CHECK parameter is set to ON (ACCESS
PASSWORD), an entry of the password is requested.
NOTE: Since ON (ACCESS PASSWORD)has been selected as factory
default, a 4-digit password entry will be requested when you access
this menu for the first time.
Enter the default password (0000) or a 4-digit password programmed
in step 6.
2
When the password matches, TAG CHECK parameter setting screen
appears.
Selecting OFF or ON(ID) disables password setting, and the
screen returns to the upper hierarchy.
If the entered password does not match, an error message is
displayed and the screen returns to the upper hierarchy menu.
3
When ON (ACCESS PASSWORD)is selected for TAG CHECK, the
password entry is requested.
Enter the 8-digit access password.
4
Choose whether or not to enable the auto unlock function.
When ONis selected, locked tags are automatically unlocked by the
access password and data write is enabled.
5
Choose whether or not to set the password to protect the error tag
detection setting.
Selecting OFF causes this menu to end, and the screen returns to
the upper hierarchy menu.
6
When ONis selected, the password can be programmed.
Enter a 4-digit password.
NOTICE: Please do not forget the programmed password as it will be
required for an access to the TAG CHECK menu afterward
. Take a
note of the password, if necessary.