5. SYSTEM MODE EO18-33027
5.4 PARAMETER SETTING
5-33
5.4.2.17 Threshold selection / THRESHOLD SELECT
・ Refractive sensor / REFLECT Set threshold mode of refractive sensor
・ Transmmisive sensor / TRANS. Set threshold mode of transmittive sensor
Refractive sensor / REFLECT
・ Manual setting / MANUAL SET Use setting value by threshold mode
・ Command setting / COMMAND SET Use setting value by command
Transmissive sensor / TRANS.
・ Manual setting / MANUAL SET Use setting value by threshold mode
・ Command setting / COMMAND SET Use setting value by command
5.4.2.18 Print method / ENERGY TYPE
・ Thermal transfer / TRANSFER
・ Direct thermal / DIRECT
Thermal transfer / TRANSFER
・ Semi regin1 Semi-regin 1
・ Semi regin2 Semi-regin 2
・ Regin1 Regin 1
・ Regin2 Regin 2
・ Reserve1 〜 Reserve6 Reserved
Direct thermal / DIRECT
・ Standard Standard
・ Reserve1 〜 Reserve9 Reserved
5.4.2.19 Power save time / PW SAVE TIME
Max. Min. Step Display Sign Integer
digit
Decimal
point
digit
0 fullfil Unit
240 1 1 Decimal Non 3 0 Non Min