5. SYSTEM MODE EO18-33027
5.8 RAM CLEAR
5-57
5.8 RAM CLEAR
Outline of RAM Clear
In the RAM Clear mode, clearing the Maintenance Counter and initializing the Parameters are possible.
After replacing the print head, ribbon motor, or platen, perform maintenance clear.
The RAM Clear menu contains the following:
MENU ITEM
System Mode / SYSTEM MODE
<6>RAM クリア / <6>RAM CLEAR
Clear Disable / NO RAM CLEAR
Counter clear / MAINTE.CNT CLEAR
All counter / ALL COUNTER
Label distance covered / FEED
Print distance / PRINT
Cut count / CUT
Others / OTHER
Parameter clear / PARAMETER CLEAR
QM type / QM TYPE
JA type / JA TYPE
CN type / CN TYPE
5.8.1 No RAM clear / NO RAM CLEAR
This is a selection to prevent wrong user operation.
5.8.2 Counter clear / MAINTE.CNT CLEAR
It clears maintenance counter, like label distance covered etc.
Initial value after maintenance counter clear
Item Initial value
Label distance covered 0 km
Print distance 0 km
Cut count 0
Head up/down count 0
Ribbon motor drive time 0 hours
Head-up solenoid driver time 0 Hours
RS-232C hardware error count 0
System error count 0
Momentary power interruption
count
0