4. Disconnect the Ribbon End Sensor Harness from the Ribbon End Sensor.
5. Separate the Sensor PCB from the Sensor Frame.
6. Fit the Sensor PCB into the Ribbon Guide.
7. Connect the Ribbon End Sensor Harness to the Sensor PCB.
Ribbon End Sensor
Sensor Frame
Sensor PCB
Sensor PCB
Ribbon Guide
Ribbon End Sensor Harness
Ribbon Guide
Ribbon End Sensor Harness
Sensor PCB

Table of Contents