4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-33031
(Revision Date: Mar. 1, 2017)
4.8 UHF RFID KIT (B-EX706-RFID-U4-US/EU/AU-R)
4-41
Platen
Actual view
4.8.2 Mounting of the RFID Module
By RF label to be used, shield label (F/C/R), antenna position (front/middle/rear), different combinations of
the mounting of the shielding plate (Y/N). Please follow the combination described in "RFID label
recommended setting sheet".
1. Attach the selected Shield Label to the bottom of the Platen Holder Block.
2. Disconnect the shielding plate from the RFID module.
Shield Label
Guide of Attachment Position
Attach the Shield Label along the rib.
<When viewed from the bottom>
Platen Holder Block
CAUTION!
DO NOT DISASSEMBLE the Platen Holder Block.
Doing so will change the adjustment.
Rib
Platen side
1. Remove the screws that secure
the antenna shield.
2. Remove the screw holding the antenna
shield
Antenna