2.PRINTER SETUP ENGLISH VERSION EO1-33048
2.11 Threshold Setting
E2-76
2.11 Threshold Setting
(Cont.)
Storing a “No Media Level” Voltage
The following is how to set a “No media level” voltage that is used to
detect a paper end.
If a “NO PAPER” is displayed even if the media has not run out yet, this
voltage needs to be set again.
(1) Remove any media from the Black Mark Sensor/Feed Gap Sensor.
(2) A real-time voltages being detected by the Black Mark Sensor and
Feed Gap Sensor are displayed.
(3) Press and hold the [RESTART] or [FEED] key for about 3 seconds.
(4) When storing a “no media level” voltage is completed, an asterisk
“*”is displayed on the right side of a voltage. Press the [PAUSE] key.
(5) The message returns to “<5>SENSOR ADJ.”.
Manual Threshold Setting
Then, set the calculated threshold voltage in the Parameter Fine
Adjustment mode.
(1) While “<5>SENSOR ADJ.” is displayed, press the [FEED] or
[RESTART] key until “<3>ADJUST SET” is displayed.
(2)Press the [PAUSE] key to enter the Parameter Fine Adjustment Mode.
(3) While “<3>ADJUST SET.” is displayed, press the [PAUSE] key
until the target sensor type is displayed.
Black Mark Sensor
Feed Gap Sensor
[PAUSE]
<3> ADJUST SET
FEED ADJ.+10.0mm
<3>ADJUST SET
<5>SENSOR ADJ.
[PE]R0.1VT4.8V*
<5>SENSOR ADJ.
Feed Gap Sensor
Black Mark Sensor
<5>SENSOR ADJ.
[PE]R0.1V
T4.8V
<3> ADJUST SET
THRESHOLD<T>1.4V
<3>ADJUST SET
THRESHOLD<R>1.0V