- 100 -
< 5 > S E N S O R A D J .
[ T R A N S . ] 2 . 4 V
< 5 > S E N S O R A D J .
[ T R A N S . ] 4 . 1 V *
< 5 > S E N S O R A D J .
[ P E ] R 0 . 1 V T 4 . 8 V
< 5 > S E N S O R A D J .
[ P E ] R 0 . 1 V T 4 . 8 V *
< 5 > S E N S O R A D J .
[ R I B B O N ] 0 . 3 V
< 5 > S E N S O R A D J .
[ R I B B O N ] 0 . 3 V *
< 5 > S E N S O R A D J .
(21) Transmissive sensor adjustment value
display:
Remove the label from the label paper
and load the backing paper. (The
label should not cover the sensor.)
[PAUSE]
(27) “*” is displayed when the reflective/
transmissive sensor adjustment is
complete.
(23) “*” is displayed when the transmissive
sensor adjustment is complete.
(24) Press the [PAUSE] key.
(25) Reflective/transmissive sensor
adjustment value display (without
paper):
Remove any paper covering the sensor.
(29) Ribbon end sensor adjustment value
display:
Set the ribbon part so that it covers the
sensor.
(26) Hold down the [RESTART] or [FEED]
key for 3 seconds or more.
[RESTART]
or
[FEED]
[RESTART]
or
[FEED]
(33) System mode menu display
(Sensor display/adjustment)
(31) “*” is displayed when the ribbon end
sensor adjustment is complete.
[RESTART]
or
[FEED]
(22) Hold down the [RESTART] or [FEED]
key for 3 seconds or more.
(30) Hold down the [RESTART] or [FEED]
key for 3 seconds or more.
[PAUSE]
(28) Press the [PAUSE] key.
[PAUSE]
(32) Press the [PAUSE] key.

Table of Contents