(3) RFID module type selection
NONE: No RFID kit is installed.
U1: The RFID kit for UHF band (B-9704-RFID-U1-US/EU) is installed.
H1: The RFID kit for HF band (B-9704-RFID-H1-QM) is installed.
H2: The RFID kit for HF band (B-SX704-RFID-H2) is installed.
U2: The RFID kit for UHF band (B-SX704-RFID-U2) is installed.
This setting will become effective after the printer power is turned off, and back to on.
(4) RFID tag type selection
c When the RFID module type is set to “NONE”:
d When the RFID module type is set to “U2”:
e When the RFID module type is set to “H2”:
FEED
RESTART
• U1: B-9704-RFID-U1-US/EU is installed.
• H1: B-9704-RFID-H1-QM is installed.
• NONE: No RFID kit is installed.
• U2: B-SX704-RFID-US is installed.
• H2: B-SX704-RFID-H2 is installed.
FEED
RESTART
• C220: 13
• Tag-it: 12
• I-Code: 11
• ISO18000-6B: 23
• EPC C1: 22
• EPC C0: 21
• NONE (When a tag type is not selected.)
• C320: 17
• EPC C1 Gen2: 24
• C240: 16
• C210: 15
• ISO15693: 14
FEED
RESTART
• NONE (When a tag type is not selected.)
• EPC C1 Gen2: 24
FEED
RESTART
• NONE (When a tag type is not selected.)
• ISO15693: 14