EasyManua.ls Logo

Toshiba BC Series - Page 33

Toshiba BC Series
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31 / 73
Copyright © 2019 Toshiba Teli Corporation, All Rights Reserved. http://www.toshiba-teli.co.jp/en/
D4296087A
* 0.4M : BC040M, 1.6M : BC160M
R/W Read / Write possible
R.O. Read Only
W.O. Write Only
N.A. Not available
Register
address
Read
Write
AC(*)
Memory
save
Default
Register name
0xC0
W.O.
-
-
Update scalable
0x1: Update registers related to scalable.
0xC4
R/W
0x0
Offset Y
0.4M:0x0 (0)0x1DC (476) OffsetY setting unit 2
0.4M:0x0 (0)0x3F8 (1016) OffsetY setting unit 2
0xC8
R/W
0.4M:0x21C
1.6M:0x438
Height
0.4M:0x40 (64)0x21C (540) Height setting unit 2
1.6M:0x40 (64)0x438 (1080) Height setting unit 2
0xCC
R/W
0x0
Offset X
0.4M:0x0 (0)0x290 (656) OffsetX setting unit 4
1.6M:0x0 (0)0x560 (1376) OffsetX setting unit 4
0xD0
R/W
0.4M:0x2D0
1.6M:0x5A0
Width
0.4M:0x40 (64)0x2D0 (720) Width setting unit 4
1.6M:0x40 (64)0x5A0 (1440) Width setting unit 4
0xD8
R/W
-
0x0
User area : address
Sets address of user area.
0x00xF(15)
0xDA
R/W
-
-
User area : data
Read /Write data to the specified by [User area : address].
The data length is specified by [User area : byte number].
0xDB
W.O.
-
-
User area : erase
0x1: erase all data in User area.
0xDC
R/W
-
0x10
User area : byte number
Sets the byte number of R/W length of user area.
0x1, 0x4, 0x8, 0x10(16)
0xF0
R/W
0x0
SequentialShutter Enable
0x0:OFF,0x1:ON
0xF1
R/W
0x1
SequentialShutter TerminateAt
Sets the number of Tables to repeat the sequence.
0x1 0x4
0xF3
R/W
0x1
SequentialShutter Entry1
Sets the UserSet number to register to the first sequence.
0x1 0x4
0xF4
R/W
0x1
SequentialShutter Entry2
Sets the UserSet number to register to the 2nd sequence.
0x1 0x4
0xF5
R/W
0x1
SequentialShutter Entry3
Sets the UserSet number to register to the 3rd sequence.
0x1 0x4
0xF6
R/W
0x1
SequentialShutter Entry4
Sets the UserSet number to register to the 4th sequence.
0x1 0x4
0xF7
W.O.
-
-
SequenceMemory Load
0x1: Load the parameters from the memory specified [Memory bank] register.
0xF8
W.O.
-
-
SequenceMemory Save
0x1: Save the parameters from the memory specified [Memory bank] register.
If camera teruned off, the data in memory for SS is erased.