111
No.
9
10
Part name
Float switch
assembly
Drain pan
Procedure
1. Detachment
1) Carry out works of Detachment of
7
and
works from 1) to 7).
2) Remove the fixing screw and then remove the
float switch assembly.
(M4,0.98" (25 mm), 1 pc.))
2. Attachment
1) Mount the float switch assembly as before with
the fixing screw.
NOTE :
When mounting, match hole of the float switch
assembly with projection of the drain pan.
2) Mount the bell mouth and fan guard as before.
(M4, 0.39" (10 mm), 8 pcs.))
3) Following to works of Attachment of
7
and
works from 2) to 5), attach the parts as before.
1. Detachment
1) Carry out works of Detachment of
4
,
6
,
7
and works from 2) to 7).
2) Remove the wiring cover by removing the
fixing screws. (M4, 0.31" (8 mm), 2 pcs.))
3) Remove the wiring box by removing the fixing
screw. (M4, 0.39" (10 mm), 1pc.))
4) Remove the fixing screws to remove the drain
pan. (M4, 0.39" (10 mm), 4 pcs.))
2. Attachment
1) Fix parts as before in order of drain cap →
drain pan → bell mouth → wiring box.
2) Following to works of Attachment of
7
and
works from 2) to 4), attach parts as before.
3) Attach the wiring cover and then attach the
electric parts box cover as before.
4) Following to works of Attachment of
4
,
attach the parts as before.
Remarks
Float switch assembly