127
No.
5
Part name
Fan, Shaft,
Bearing,
Coupling,
Fan case
Procedure
Fan quantity and mounting construction
Remarks
NOTE :
There is a bearing spacer (2 pcs.) between
the cover which fixes the bearing and the base.
Be careful not to miss the bearing spacer.
5) Loosen the hexagon socket head screw and
then remove the shaft together with the fan.
6) Loosen the hexagon socket head screw and
then remove the fan from the shaft.
Loosen the hexagon socket head screws
(2 positions) of bearing and then remove
them from the shaft if necessary.
Model name
SP180CT-UL
SP240CT-UL
SP300 to
420CT-UL
Quantity
2 fans
3 fans
4 fans
Mounting construction
Direct mounting to both sides of
fan motor
Shaft is used and one side of
shaft is supported by bearing.
Shaft is used and the middle part
of shaft is supported by bearing.
1. Detachment
NOTE :
The following description is detachment
method of AP036 to AP042 class as repre-
sentative.
1) Carry out works of Detachment of
2
and
1), 2).
2) Remove the hooking claws at both sides of
the fan case (bottom).
3) Pull out and remove the fan case (bottom)
from the partition panel.
4) Remove the bearing from the main unit by
removing the bolts (2 positions) which fix
the bearing. (M8, 0.47"(12 mm), 2 pcs.))
(SP300 to 420 models only)
AP180
AP240
AP036 to
AP042
Hooking claw