Initial setting of "Cooling storage position"
Louver : (Directs downward 35.3°)
Item
7. Louver control
1) Louver
position
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
Description
Swing operation is performed in width 35° with the stop position as
the center.
If the stop position exceeds either upper or lower limit position,
swing operation is performed in width 35° from the limit which the
stop position exceeded.
3) Swing
2) Air direction adjustment
The position is automatically controlled initial setting of "Cooling
The set louver position is stored in memory by the microcomputer,
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
storage position" Louver : (Directs downward ).
and the louver returns to the stored position when the next operation
is performed. (Cooling memory position)
Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.
The louver position can
be arbitrarily set up by
pressing [FIX] button.
– 34 –
FILE NO. SVM-13071
35.3°
Fixed
Position
before start
swing
Upper Limit
Position.
Lower Limit
Position
30
o
5
o
Swing
range 35
o
Upper Limit
Position.
Lower Limit
Position.
Fixed Position
before start
swing.
17.5
o
17.5
o
Swing
range 35
o