35
Item
8. ECO
operation
Operation flow and applicable data, etc.
When pressing [ECO] button on the remote controller, a
Economic operation is performed.
<Cooling operation>
This function operates the air conditioner with the
difference between the set and the room temperature as
shown in the following figure.
Description
9. Temporary
operation
Pressing [RESET] button starts the temporary opera-
tion of [AUTO] operation. When keeping [RESET]
button pressed for 10 seconds or more, the temporary
[COOL] operation is performed.
Filter lamp ON
Press RESET button.
Did you press [RESET] button
for 3 seconds or more?
Did you press [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
YES
YES
NO
NO
NO
YES
Temporary [AUTO] operation
Temporary [COOL] Operation
1) When pressing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pressed
for 3 seconds or more, Pi, Pi, Pi sound
is heard and [AUTO RESTART] control
is changed.
3) When keeping [RESET] button pressed
for 10 seconds or more, Pi sound is
heard and the temporary [COOL]
operation starts.
4) If the filter lamp goes on, press [RESET]
button to go off the filter lamp, and then
press [RESET] button again.
5) To stop the temporary operation, press
the button again.
FILE NO. SVM-13071
1) The control target temperature
increase 1.0°F (0.5ºC) per hour
up to 3.5°F (2°C) starting from the
set temperature when ECONO
2) The indoor fan speed is depend
on presetting and can change
every speed after setting ECO
operation.
<Cooling operation>
3) The compressor speed is
controlled as shown in the left
figure.
has been received.
* 12 (DRY max - COOL min) /6 x 5 + COOL min
* 11 (DRY max - COOL min) /6 x 4 + COOL min
* 10 (DRY max - COOL min) /6 x 3 + COOL min
* 9 (DRY max - COOL min) /6 x 2 + COOL min
* 8 (DRY max - COOL min) /6 x 1 + COOL min
(Room temp. – Set temp.)
Hz
09EKCV-UL
12EKCV-UL
Cool min
DRY max
20
35
11
31
6.3
5.5
4.5
2.7
2.0
-2.0
-3.5
10.0
11.0
11.7
9.0
8.0
7.0
3.5
1.0
-1.0
(°C)°F
during the ECO operation.
(3.5)
(3.0)
(2.5)
(1.5)
(1.0)
TSC
(-1.0)
(-2.0)
(5.5)
1H 2H
11
10
7
6
5
4
3
2
1
OFF
Dry Max
*12
*11
*
9
*8
*10
0.0
(6.0)
(6.5)
3H
4H
(5.0)
(4.5)
(4.0)
(2.0)
(0.5)
(-0.5)
12
9
8
Time
Zone
Frequency
FAN
Min
Hz
The indoor fan speed is not controlled and can be selected