High-Wall Type
Installation Manual
–41–
Toshiba
: Lighting : Flashing : OFF : The air conditioner automatically enters the auto-address setting mode.
ALT: When two LEDs are flashing, they flash alternately. SIM: When two LEDs are flashing, they flash in synchronization.
Receiving unit display OR: Orange GR: Green
P26 ALT
Outdoor unit inverter
Idc activated
Outdoor
IGBT, outdoor unit P.C. board,
inverter wiring, compressor ---
Short-circuit protection for
compressor drive circuit devices
(G-Tr/IGBT) was activated.
Entire
stop
P29 ALT
Outdoor unit position
error
Outdoor
Outdoor unit P.C. board, high-
pressure switch --- Compressor
motor position error was
detected.
Entire
stop
P31 ALT
Other indoor unit
error
Indoor
Another indoor unit in the group
is raising an alarm.
Entire
stop
E03/L07/L03/L08 alarm check
locations and error description