313-01 Signalling Method
)%
, n,
+ROG
n = 1. None (default)
2. ANI/DNIS-MCI
3. ANI/DNIS-Sprint
4. CLASS (Caller ID)
Specify the format for the interface being used.
313-02 Signalling Contents
)%
, n,
+ROG
n = 1. ANI and DNIS (default)
2. ANI only
3. DNIS only
4. DID only
Specify the contents of the ANI/DNIS format.
313-03 CLASS Equipment
Position
)%
, xxyyzz,
+ROG
xx = Cabinet 01 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
If the CLASS type is chosen, the trunk must be assigned to a Caller
ID circuit. Enter the RCIU/RCIS equipment number as xxyyzz.
Notes
• CLASS equipment numbers are required when assigning a trunk
to a RCIU/RCIS circuit.
• It can also be used to display the equipment location of existing
caller ID circuit to trunk assignments. Example: If the trunk should
be connected to a caller ID circuit (RCIU/RCIS) in cabinet shelf 5,
slot 2, circuit 3, enter 050203.
yy = Slot 01~8 (CTX100),
01~10 (CTX670)
zz = Circuit 01~08
315
T1 Trunk Card
,
+ROG
This command assigns T1 Trunk Card Data to the system.
315-00 T1 Equipment
Location
xxyy,
+ROG
xxyy xx = Cabinet 01,
yy = slot 01, 03, 05, or 07
Enter the RDTU PCB equipment location as xxyy:
Example: If the RDTU is installed in cabinet shelf 5, slot 3, enter
0503.
Cabinet numbers:
CTX100: Select 01 for Base and Expansion cabinet.
CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
CTX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670: Select 01~08 for Base slots and 01~10 for Expansion slots.
...or xx = Cabinet 02~07,
yy = slot 01, 03, or 05
315-01 Coding Format
)%
, n,
+ROG
n = 1. None
2. PZC
3. B8ZS (default)
4. ZCS
Select the Coding Format.
315-02 Frame Format
)%
, n,
+ROG
n = 1. None
2. SF mode
3. ESF mode (default)
Select the Frame Format.
315-03 Time Slots n = 1. None
2. 8 Time Slots (default)
3. 16 Time Slots
4. 24 Time Slots
Set the number of Time Slots to be used.
315-04 Receive PAD
)%
, n,
+ROG
,
+ROG
n = 1. None
2. Plus 6 dB
3. Plus 3 dB
4. Zero dB (default)
5. Minus 3 dB
6. Minus 6 dB
7. Minus 9 dB
8. Minus 12 dB
9. Minus 15 dB
Select the Receive PAD values.
Table 13-28 Programs 303~315 (continued)