Telephone Button Programming
900 Series Programs
Strata CTX Programming - Part 3: Telephone Button Programming 11/03 13-97
Telephone Button
Programming
To access programming parameters
1. Press
)% to choose Initialize Level 1 or 2.
2. Press
+ROG twice to initialize.
Important! Choosing Initialize Level 1 without installing a SmartMedia Card deletes all programmed
data and returns your Strata CTX to factory default settings. All previously programmed
data is lost.
Restoring Data from SmartMedia
When initializing with Level 1 you can restore custom data that was previously programmed and stored on
a SmartMedia card. To do so, follow the steps below.
1. Install a SmartMedia card that contains the
Prgdata directory with the default.dat file. The
default.dat file contains your custom settings and can be created by running Data Backup. See
“Data Backupon page 13-105.
Important! A CTX default.dat database can only be restored to a CTX software version that is the
same or higher than the CTX software version on which the default.dat file was created.
Examples: A
default.dat created on CTXR2.0 MF029 can be restored on an R2.0
MF030, MF031 and higher R2.1MG0XX, R2.2 MF0XX (XX = 01~99, but it cannot be
restored on R2.0 MF012, MF011 and lower, or R1.X ME0XX, MD0XX, etc.
2. After installing the SmartMedia card, run System Initialization using Initialize Level 1.
Restoring data from the SmartMedia card may take an hour or more. To verify completion of the restore
process access, the Programming Mode from a telephone and enter your password. If the system
enables you to continue, the data restore process is complete.
Note During the restore process, the telephone LCD may display date and time data. This does not
necessarily indicate completion of the restore process.
Display Version
This program enables you to view current software versions for the Strata CTX system and installed
options.
Active – As the name implies, this is the current active software operating the Strata CTX system.
Standby – This is a software version released prior to the active version. It acts as a backup in the event
problems are experienced by the Active version.
Program Number(s): 901
Prerequisite Program:
None
Reference: None
Access Sequence: Login to programming mode from your telephone button pad:
+ROG.
At the PASSWORD= prompt, Enter your password and press+ROG.
At the PROG= prompt enter  and press +ROG