December 2002 TOSHIBA TEC 7 - 27 e-STUDIO160/200/250 SCANNER
Fig. 7-8-27
059-1
Wire
Wire
Roller
Wire holder
Screw
Carriage 2
Roller
Wire
11. Mount the clip jig to prevent the dislocation of
wire wound on scanner drive shaft and secure
wire.
Notes: 1. When the wire holder clip jig is installed,
do not slide or loosen the wound wire.
2. The wire holder clip jigs are the same
time for the front and rear sides.
3. Be careful when installing the clip jig.
12. Loosen 2 screws retaining wire holder.
13. Detach wire on the side where it is hooked and
fixed to scanner frame and release wire from
roller if carriage 2.
14. Remove carriage 2 by turning it by 45 degrees.
Fig. 7-8-28
15. Remove spring plate securing mirror 2 and re-
move mirror 2.
Note: Clean the surface of mirror 2 if dirty.
Fig. 7-8-29
Carriage 2
060-4
Mirror 2
Spring plate
Spring plate
Spring plate
060-2