e-STUDIO160/200/250 COPYING PROCESS 3 - 12 December 2002 TOSHIBA TEC
[C] Drum
1. Remove the toner cartridge and the process
unit.
2. Detach the separation claw. (See Fig. 3-4-1.)
3. Detach the drum assembly. (See Fig. 3-4-2.)
4. Remove 2 screws and detach the drum bracket.
5. Detach the drum.
Note: When the drum is replaced with a new one,
apply patting powder (lubricant) on the en-
tire surface of the new drum (including both
edges to where the OPC is not coated).
Fig. 3-4-8
[D] Drum cleaning blade
1. Remove the toner cartridge and the process
unit.
2. Detach the separation claw. (See Fig. 3-4-1.)
3. Detach the drum assembly. (See Fig. 3-4-2.)
4. Detach the DLE PWA assembly.
(See Fig. 3-4-3.)
5. Detach the main charger assembly.
(See Fig. 3-4-4.)
6. Detach the drum. (See Fig. 3-4-8.)
7. Pull out 2 pins and detach the drum cleaning
blade.
Fig. 3-4-9
Note: Be sure not to touch the contact part of the
drum cleaning blade and drum.
Drum
Screw
Drum bracket
3-8-08
Pin
Drum cleaning
blade
3-8-09