e-STUDIO167/207/237 © 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved
SCANNER
6 - 24
(4) Lift up the CIS unit, disconnect 1 connector
on the bottom of the CIS unit, and then take
off the CIS unit.
Notes:
• Take care not to contaminate the CIS unit
surface with fingerprints, dust or such.
• Be sure to perform "05-310" with the
platen cover or the ADF/RADF closed
after replacing the CIS unit.
Fig. 6-30
(5) Release 2 latches each to take off 2 original
glass guides from the CIS unit.
Fig. 6-31
CIS unit
Connector
Original glass guide