e-STUDIO200L/202L/230/232/280/282 FUSER UNIT June 2004 © TOSHIBA TEC
13 - 16
[G] Cleaning roller
[H] Thermistor
(1) Take off the pressure roller
(! P.13-14 "[E] Fuser roller").
(2) Remove 2 screws and take off the cleaning
unit.
Fig.13-20
(3) Press down the holder and take off the
cleaning roller.
Fig.13-21
(1) Place the fuser unit upside down.
(2) Release the latch and take off the harness
cover.
Fig.13-22
Cleaning unit
Cleaning roller
Holder
Harness cover