e-STUDIO200L/202L/230/232/280/282 OUTLINE OF THE MACHINE June 2004 © TOSHIBA TEC
2 - 24
7) Thermistors and thermostats
8) Transformer
Symbol Name Function Remarks P-I
THMO1 THERMO-SCN-DH
Scanner damp heater thermostat
Controlling the temperature of the scan-
ner damp heater
* ASD/AUD/CND/SAD/ASU/TWD/
IRD/ARD/KRD models: Standard
* NAD/MJD models: Option
P.2-6
"Fig. 2-6"
P11-I37
THMO2 THERMO-FSR-F
Fuser front thermostat
Preventing overheating in the fuser unit P.2-13
"Fig. 2-
16"
P30-I10
THMO3 THERMO-FSR-C
Fuser center thermostat
Preventing overheating in the fuser unit P.2-13
"Fig. 2-
16"
P30-I10
THMO4 THERMO-DRM-DH
Drum damp heater thermostat
Controlling the temperature of the drum
damp heater
* ASD/AUD/CND/SAD/ASU/TWD/
IRD/ARD/KRD models: Standard
* NAD/MJD models: Option
P.2-8
"Fig. 2-9"
P5-I19
THMS1 THMS-DRM
Drum thermistor
Detecting the temperature at the drum
surface
P.2-8
"Fig. 2-9"
P28-I49
THMS2 THMS-C-HTR
Center thermistor
Detecting the surface temperature at
fuser roller center
(for controlling the temperature of the
center heater lamp)
P.2-13
"Fig. 2-
16"
P30-I40
THMS3 THMS-S-HTR
Side thermistor
Detecting the surface temperature at the
rear side of the fuser roller
(for controlling the temperature of the
side heater lamp)
P.2-13
"Fig. 2-
16"
P30-I40
THMS4 THMS-EDG-HTR
Edge thermistor
Detecting the surface temperature at the
edge of the fuser roller
(for preventing overheating)
P.2-13
"Fig. 2-
16"
P30-I40
Symbol Name Function Remarks P-I
HVT PS-HVT
High-voltage transformer
Generating high-voltage and supplying it
to the following sections
Needle electrode
Main charger grid
Developer bias
Transfer bias
Separation bias
Transfer guide bias
P.2-15
"Fig. 2-
18"
P6-I1
05/11