e-STUDIO160/200/250 SCANNER 7 - 18 December 2002 TOSHIBA TEC
Fig. 7-8-1
CN49
RELAY PWA
Clamp
Clamp
CN111
FUS PWA
039-1
039-3
Fig. 7-8-2
Screw
Clamp
Washer
7.9 Disassembly and Replacement
[A] Scanner assembly
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, detach it.
2. If a STP (KK-1600) is attached to the copier,
detach it.
3. Detach the manual pocket.
4. If a Finisher (MJ-1011) is attached to the copier,
detach the finisher plate.
5. Detach rear cover. (See Fig. 2-6-1)
6. Detach top cover. (See Fig. 2-6-2)
7. Detach scanner cover. (See Fig. 2-6-3)
8. Detach top cover L. (See Fig. 2-6-4)
9. Detach top cover R. (See Fig. 2-6-5)
10. Detach control panel front cover.
(See Fig. 2-6-6)
11. Detach control panel bottom cover.
(See Fig. 2-6-7)
12 If a FAX kit (GD-1061) is attached to the copier,
detach the FAX PWB and NCU PWB.
13. If a PCL kit (GA-1031) is attached to the copier,
detach it.
14. If a NIC kit (GF-1110) or I-FAX (GD-1070) is
attached to the copier, unplug the connectors
for CN14 and CN17.
15. If finisher (MJ-1011) is attached to the copier,
detach the finisher PWA.
16. Remove MAIN PWA.
(See Fig. 2-6-25 and 2-6-26)
17. Remove the one screw to release the washer
and clamp.
18. Detach one connector from RELAY PWA
(CN49) and release 2 clamps.
19. If the damp heater is installed, remove the screw
and detach FUS PWA cover. (See Fig. 2-6-34)
20. If the damp heater is installed, detach the damp
heater harness connector and release the three
clamps.