PREVENTIVE MAINTENANCE (PM)
7 - 62
7.7.10 Image quality control unit
Fig. 7-71
* J1: Image quality sensor, J2: Sensor shutter, J3: Image position aligning sensor
Clean the image quality sensor, image position aligning sensor (Front/Center/Rear) and the
sensor shutter when replacing the transfer belt cleaning blade and the blade seal, or the transfer
belt itself.
Items to check Cleaning
Lubrica
tion/
Coating
Replacement
Operation
check
Parts
list
<P-I>
(x 1,000
sheets)
(x 1,000 drive
counts)
J1 Image quality sensor A R3 R3 6-6
J2 Sensor shutter B R3 R3 6-28
J3 Image position aligning
sensor
(Front/Center/Rear)