e-STUDIO166/206 © February 2007 TOSHIBA TEC CORPORATION All rights reserved
SCANNER
6 - 12
6.6 Disassembly and Replacement
[A] Original glass
(1) Remove 2 rubber caps, 2 screws, and take
off the original glass holder while sliding it to
the right.
Note:
The rubber caps are not installed in the
equipment for NAD, CND, AUD, TWD, KRD
and ARD.
Fig. 6-7
(2) Remove 2 rubber caps, 2 screws, and take
off the original glass.
Notes:
1. When handling the original glass, take
care not to contaminate the surface with
fingerprints or such.
2. Do not place the original glass directly on
the floor.
3. When installing the original glass, fit 2
guides of the original glass in the groove
of the scanner top cover.
4. The rubber caps are not installed in the
equipment for NAD, CND, AUD, TWD,
KRD and ARD.
Fig. 6-8
(3) Take off the ADF original glass.
Fig. 6-9
Original glass holder
Rubber cap
Original glassRubber cap
ADF Original glass