December 2005 © TOSHIBA TEC e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 49
2
540-0 Fuser Temperature
drop switching
time setting
during printing
(Thick paper/
Center ther-
mistor)
The first
drop
ALL 20
<0-200>
M This code is valid only
when “20” is set to 08-
535.
Setting value x 5 sec.:
from 0 to 1,000
sec.later
Thick paper:
Thick Paper1/Thick
Paper2/OHP/Envelope
4
540-1 The sec-
ond drop
ALL 48
<0-200>
M 4
540-2 The third
drop
ALL 100
<0-200>
M 4
540-3 The fourth
drop
ALL 100
<0-200>
M 4
541-0 Fuser Temperature
drop switching
time setting
during printing
(Thick paper/
Side ther-
mistor)
The first
drop
ALL 20
<0-200>
M This code is valid only
when “20” is set to 08-
535.
Setting value x 5 sec.:
from 0 to 1,000
sec.later
Thick paper:
Thick Paper1/Thick
Paper2/OHP/Envelope
4
541-1 The sec-
ond drop
ALL 48
<0-200>
M 4
541-2 The third
drop
ALL 100
<0-200>
M 4
541-3 The fourth
drop
ALL 100
<0-200>
M 4
550 Image Default setting of original
mode
PPC 0
<0-2>
SYS 0: Text/Photo
1: Photo 2: Text
1
604 User
interface
Default setting for APS/
AMS
PPC 0
<0-2>
SYS 0: APS (Automatic
Paper Selection)
1: AMS (Automatic
Magnification Selec-
tion)
2: Not selected
1
607 User
interface
Default setting of RADF
mode
PPC 0
<0-1>
SYS 0: Continuous feeding
(by pressing the
[START] button)
1: Single feeding
(by setting original
on the tray)
1
611 User
interface
Book type original priority PPC 0
<0-1>
SYS 0: Left page to right
page
1: Right page to left
page
1
618 User
interface
Default setting when mixed
size originals are set on
ADF
PPC 0
<0-1>
SYS 0: Scanned as all in
same size
1: Scanned as each
original size
1
641 User
interface
Automatic Sorting Mode
setting (ADF)
PPC 2
<0,2>
M 0: Invalid
2: SORT
1
642 User
interface
Default setting of Sorter
Mode
PPC 1
<0,1>
M 0: SORT
1: GROUP
1
655 General Reset the 05/08 codes - - - Returns the set value
for the 05/08 code to its
default value.
However, various
counter values of the 08
codes are not reset.
-
672 General Initialization of Access
code
- - SYS Initializing of the Access
code
* Key in the code and
press the [START]
button to perform
the initialization.
3
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
06/05