e-STUDIO181/211 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 22
305 Scanner Image location adjustment
of secondary scanning
direction
(scanner section)
ALL 120
<51-206>
SYS When the value
increases by “1”, the
image shifts by approx.
0.0640 mm toward the
trailing edge of the
paper.
During this adjustment,
the density LED blinks.
1
306 Scanner Image location adjustment
of primary scanning
direction
(scanner section)
ALL 130
<121-
136>
SYS When the value
increases by “1”, the
image shifts by approx.
0.169 mm toward the
front side of the paper.
During this adjustment,
the density LED blinks.
1
310 Scanner Forced performing of peak
detection
ALL - - Activates the light
intensity adjustment
control
During this adjustment,
the density LED blinks.
7
311 Scanner LED (R) current effective
value setting
ALL 76
<0-255>
SYS Displays total of the
initial value and light
intensity correction
value.
1
312 Scanner LED (B) current effective
value setting
ALL 62
<0-255>
SYS Displays total of the
initial value and light
intensity correction
value.
1
313 Scanner LED (YG) current effective
value setting
ALL 160
<0-255>
SYS Displays total of the
initial value and light
intensity correction
value.
1
340 Scanner Reproduction ratio
adjustment of secondary
scanning direction
(scanner section)
ALL 125
<76-181>
SYS When the value
increases by “1”, the
reproduction ratio in the
secondary scanning
direction (vertical to
paper feeding direction)
increases by approx.
0.0947%.
During this adjustment,
the density LED blinks.
1
350 Scanner Shading
position
adjustment
Original
glass
ALL 128
<118-
138>
SYS 0.064 mm/step
During this adjustment,
the density LED blinks.
1
351 ADF ALL 128
<118-
138>
SYS 1
354 ADF Adjustment of ADF paper
alignment
ALL 10
<0-20>
SYS When the value
increases by “1”, the
aligning amount
increases by approx.
0.4 mm.
1
357 ADF Fine adjustment of ADF
transport speed
ALL 50
<0-100>
SYS When the value
increases by “1”, the
reproduction ratio of the
secondary scanning
direction when using the
ADF increases by
approx. 0.1%.
During this adjustment,
the density LED blinks.
1
Adjustment mode (05)
Code
Classifi
cation
Items
Funct
ion
Default
<Accept
able
value>
RAM Contents
Proce
dure