12
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO182/212/242
FUSER / EXIT UNIT
12 - 17
(4) Close the guide, and then take off the guide
by sliding its rear hinge to the right side.
Fig. 12-18
(5) Remove 1 spring and take off the guide while
the guide is being slid to the rear side.
Fig. 12-19
(6) Remove the Mylar.
(7) Disconnect 1 connector, release 2 latches,
and then take off the exit sensor.
Fig. 12-20
Note:
When installing the guide, secure the spring
to the hook of the fuser unit and the other
end of the spring to the guide.
Fig. 12-21
1
2
Guide
Spring
Exit sensor
Connector
Mylar
SpringHook Guide