11)Skew (inclined image)
Fig. 5-11
Defective area Step Check items Prescription
Drawers
LCF
1 Is the drawer or LCF properly
installed?
Install the drawer or LCF properly.
2 Is there too much paper in the drawer
or LCF?
Reduce paper to 550 sheets or less.
(2500 sheets or less/stack for LCF)
3 Is the corner of the paper folded? Change the direction of the paper
and set it again.
4 Are the side guides of the drawer or
LCF properly installed?
Adjust the position of the side guides.
Feed roller 5 Is the surface of the feed roller dirty? Clean the feed roller surface with
alcohol, or replace the roller.
Rollers 6 Are the roller and shaft secured? Check and tighten the E-rings, pins,
clips and setscrews.
Registration roller 7 Is the spring detached from the regis-
tration roller?
Attach the spring correctly. Clean the
roller if it is dirty.
Pre-registration guide 8 Is the pre-registration guide properly
installed?
Correct it.
Carriage-1 9 Is the carriage-1 slanted? Adjust the carriage-1.