SCANNER
6 - 22
[F] Carriage-1
(5) Move the carriage-1 to the position where
the exposure lamp is seen through the cutout
of the frame.
Note:
Rotate the drive pulley to move the carriage.
Fig. 6-32
(6) Remove 1 screw. Lift up the exposure lamp
and take it off by pulling out toward you.
Note:
Make sure to hold only the black molded part
of the exposure lamp. Do not touch any other
part than this black molded part.
Fig. 6-33
(1) Take off the original glass
( P.6-17 "[A] Original glass").
(2) Take off the front upper cover and upper rear
cover
( P.2-32 "[E] Front upper cover", P.2-34
"[I] Upper rear cover").
(3) Move the carriage-1 to the position shown in
the figure at right, and match the positions of
each hole and screw. Remove 2 screws.
Fig. 6-34
Carriage-1
Exposure lamp
Carriage-1