e-STUDIO200L/202L/203L/230/232/233/280/282/283 © 2004 - 2008 TOSHIBA TEC CORPORATION All rights reserved
SCANNER
6 - 28
[M] Scan motor
(1) Take off the rear cover upper rear cover
( P.2-31 "[C] Rear cover", P.2-34 "[I]
Upper rear cover").
(2) Disconnect the connector of scan motor.
Fig. 6-48
(3) Remove 3 screws and take off the scan
motor.
Note:
When installing, use a stepped screw to fix
the left rear point.
Fig. 6-49
Notes:
When installing the scan motor, use the belt
tension jig (spring). The procedure is as fol-
lows.
1. Fix the screw A.
2. Temporarily fix the screw B and C.
3. Hook the belt tension jig to the motor
bracket and the flame.
4. The scan motor is pulled by the belt ten-
sion jig. Fix the screw B and then C at the
stopped position.
5. Remove the belt tension jig.
Fig. 6-50
Scan motor
Belt tension jig
A
B
C