e-STUDIO200L/202L/203L/230/232/233/280/282/283 © 2004 - 2008 TOSHIBA TEC CORPORATION All rights reserved
DEVELOPMENT SYSTEM
12 - 14
(5) Remove 2 screws on both ends of the doctor
sleeve and remove 2 coil springs.
Note:
When the screws on both ends of the doctor
sleeve are removed, be sure to adjust the
doctor sleeve gap (0.45±0.05 mm) after
assembling.
(Refer to Service Handbook Chap. 3.9)
Fig. 12-19
(6) Remove 1 screw and plate spring.
(7) Remove 1 screw and take off the polarity
adjustment lever.
Note:
Make a note of the position where the polar-
ity adjustment lever is pointing. (Mark the
position if needed.) When reassembling,
match the polarity adjustment lever with the
previously marked position on the scale.
Fig. 12-20
(8) Remove 2 screws and take off the bracket.
Fig. 12-21
Screw Screw
Coil spring Coil spring
Plate spring
Polarity adjustment lever
Connector
Bracket