June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 157
2
237 Paper
feeding
Paper size (ST-R) feeding/
widthwise direction
ALL 216/140
<182-
432/140-
297>
M 10
238 Paper
feeding
Paper size (COMPUTER)
feeding/widthwise direction
ALL 356/257
<182-
432/140-
297>
M 10
239 Paper
feeding
Paper size (FOLIO) feed-
ing/widthwise direction
ALL 330/210
<182-
432/140-
297>
M 10
240 Paper
feeding
Paper size (13” LG) feed-
ing/widthwise direction
ALL 330/216
<182-
432/140-
297>
M 10
241 Paper
feeding
Paper size (8.5”X8.5”)
feeding/widthwise direction
ALL 216/216
<182-
432/140-
297>
M 10
242 Paper
feeding
Paper size (Non-standard)
feeding/widthwise direction
ALL 432/279
<148-
432/105-
297>
SYS 10
243 Paper
feeding
Memory 1
Paper size (bypass feed-
ing/non-standard type)
feeding/widthwise direction
ALL 148/100
<148-
432/100-
297>
SYS Registers the paper
size of bypass feed
(non-standard type) into
[MEMORY 1].
10
244 Paper
feeding
Paper size (8K) feeding/
widthwise direction
ALL 390/270
<182-
432/140-
297>
M 10
245 Paper
feeding
Paper size (16K-R) feed-
ing/widthwise direction
ALL 270/195
<182-
432/140-
297>
M 10
247 Paper
feeding
Memory 2
Paper size (bypass feed-
ing/non-standard type)
feeding/widthwise direction
ALL 148/100
<148-
432/100-
297>
SYS Registers the paper
size of bypass feed
(non-standard type) into
[MEMORY 2].
10
248 Paper
feeding
Memory 3
Paper size (bypass feed-
ing/non-standard type)
feeding/widthwise direction
ALL 148/100
<148-
432/100-
297>
SYS Registers the paper
size of bypass feed
(non-standard type) into
[MEMORY 3].
10
249 Paper
feeding
Memory 4
Paper size (bypass feed-
ing/non-standard type)
feeding/widthwise direction
ALL 148/100
<148-
432/100-
297>
SYS Registers the paper
size of bypass feed
(non-standard type) into
[MEMORY 4].
10
250 Mainte-
nance
Service technician tele-
phone number
ALL 0
<32 dig-
its>
SYS A telephone number
can be entered up to 32
digits. Use the [Monitor/
Pause] button to enter a
hyphen (-).
11
Setting mode (08) <e-STUDIO202L/232/282>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
05/11