ERROR CODE AND TROUBLESHOOTING
8 - 116
Punch motor clock sensor (S37)
abnormality
Measure the voltage on pin CN3.6 on the hole punch control
PC board (HP). Then check that the measured voltage is 1V or
lower when not shielded and within the range of 5V5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Faulty cables and connectors Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connector. (Hole punch control PC board (HP): CN3, CN6)
Hole punch control PC board (HP)
abnormality
If the error still occurs after replacing the motor, sensors and
connectors, exchange the hole punch control PC board (HP).
Probable cause Checking and measures