SELF-DIAGNOSIS MODES
2 - 179
9090 General Printer all clear ALL - M If the data of the self-
diagnosis 05/08 code
become abnormal,
performing 08-4582 can
restore them. If not,
perform this code. All
data of the self-
diagnosis 05/08 code
with “M" in the "SRAM"
field are initialized,
except the destination
setting data.
Perform this code if the
above problem occurs
or the data of the self-
diagnosis 05/08 code
and the backup data
are damaged after
replacing the LGC
board and performing
08-4582.
Procedure:
1. Set 08-201.
2. Perform 08-9090.
3. Perform 08-4581.
4. Set 08-203 to "0".
If you have got the
order wrong, repeat the
procedure from step 1.
After this code is
performed, it is
necessary to replace
the developer material
and to adjust the auto-
toner sensor. Since the
information of the PM
counter is initialized,
enter it again as
required.
3
9117 General Raw printing job
(Blank page will not be
printed)
PRT 0
<0-1>
SYS 0: OFF
1: ON
1
Setting mode (08)
Code
Classific
ation
Items
Functi
on
Default
<Acceptable
value>
Boa
rd
Contents
Proce
dure