e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSIS MODES
2 - 52
2084 Image
processi
ng
Transfer cleaning bias
adjustment (negative)
ALL 41
<0-255>
M When the high-voltage
transformer is replaced,
the transfer cleaning bias
needs to be adjusted with
this code.
The larger the setting
value is, the higher the
value of the current
(more negative) is. This
causes a reduction in the
toner adhering to the
transfer roller and an
improvement in the
cleaning performance.
Perform this adjustment
after the process units
(cleaner and developer
unit) have been removed.
When the high-voltage
transformer is replaced,
adjusting with the
following codes need to
be performed in addition
to this adjustment.
05-205, 05-210, 05-221,
05-234
3
7025 Image Background offset
adjustment for RADF
PPC 128
<0-255>
SYS The larger the
adjustment value is, the
lighter the background
becomes. The smaller
the adjustment value is,
the darker the
background becomes.
1
7033 Image Backgroun
d
adjustment
(Automatic
density
adjustment)
Text/
Photo
PPC 128
<0-255>
SYS The larger the value is,
the lighter the
background becomes.
The larger the value is,
the lighter the
background becomes.
1
7034 Image Text PPC 128
<0-255>
SYS 1
7041 Image Backgroun
d
adjustment
(Manual
density
adjustment)
Text/
Photo
PPC 128
<0-255>
SYS 1
7042 Image Text PPC 128
<0-255>
SYS 1
7043 Image Backgroun
d
adjustment
(Automatic
density
adjustment)
Photo PPC 128
<0-255>
SYS 1
7048 Image Backgroun
d
adjustment
(Black /
Manual
density
adjustment)
Photo PPC 128
<0-255>
SYS 1
Adjustment mode (05)
Code
Classific
ation
Items
Funct
ion
Default
<Acceptable
value>
Boa
rd
Contents
Proce