Suspend when quota is
empty
Sets whether the process is suspended
immediately or suspended after the job is
completed if quota is used up.
0: Suspended immediately
1: Suspended after the job is finished
Service call checking period
setting
0: No checking period specified (= Calls service
technician immediately)
1: 10 minutes
2: 30 minutes
3: 1 hour
4: 6 hours
5: 12 hours
6: 24 hours
7: 48 hours
8: 7 days
9: 1 month
10: 1 year
11: 5 years
12: Not limited (= Calls service technician if such
error has occurred in the past even once or more)
Service Notification setting
Enables to set up to 3 E-mail addresses to be sent.
(08-9794, 9607, 9608)
0: Invalid
1: Valid (E-mail)
2: Valid (FAX)
Remote-
controlled service
Destination E-mail address 1
Remote-
controlled service
Total counter information
transmission setting
Remote-
controlled service
Total counter transmission
date setting
Remote-
controlled service
Temporary communication
password setting
Sets a temporary communication password. The
password can be entered in alphanumeric
characters (A to Z, a to z, 0 to 9) up to 10 digits.
The entered password is displayed with "*" on the
touch panel and the self-diagnostic lists.
(Maximum 10 digits, minimum 5 digits)
Sets the authentication mode when "0: (Internal
authentication)" is selected in the code 08-9293.
0: Card ID differs from the User ID
1: Card ID is the same as the User ID
Forcible mode change in
toner empty status
0: SLEEP MODE
1: AUTO POWER SAVE
2: READY
Firmware version of printer
loader section
ROM version of
printer optional
tray
ROM version of
printer optional
tray