12
March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 DEVELOPER UNIT
12 - 19
[B-2] Recycle toner transport motor (M8) and Hopper motor (M7)
[C] Developer unit
[D] Developer material
(1) Disconnect 1 connector, remove 2 screws,
and then take off the recycle toner transport
motor.
(2) Disconnect 1 connector, remove 2 screws,
and then take off the hopper motor.
Fig.12-21
(1) Take off the toner recycle unit.
( P.12-18 "[B] Toner recycle unit")
(2) Rotate the L-shaped shaft upward to release
the lock.
(3) Disconnect 1 connector and pull out the
developer unit to the front side.
Fig.12-22
(1) Take off the developer unit.
( P.12-19 "[C] Developer unit")
(2) Remove 2 screws to take off the top cover.
Fig.12-23
Recycle toner transport motor
Hopper motor
Connector
Screw
Screw
L-shaped shaft
Developer unit