e-STUDIO520/600/720/850 FUSER UNIT March 2005 © TOSHIBA TEC
14 - 26
[H] Fuser roller
(1) Take off the fuser unit
( P.14-18 "[B] Fuser unit").
(2) Take off the cleaning web unit
( P.14-19 "[C] Cleaning web unit / Clean-
ing web").
(3) Loosen 2 pressure screws completely.
Fig.14-33
(4) Remove 2 screws and take off the fuser unit
cover (rear).
(5) Open the lower separation finger unit
( P.14-24 "[F] Lower separation finger unit
/ Lower separation finger").
(6) Remove 2 screws and open the entrance
guide unit.
Fig.14-34
(7) Remove 2 screws, release 2 harness clamp
and take off the bracket with releasing the
catching section.
Fig.14-35
Pressure screw
Fuser unit cover
(
rear
)
Screw
Entrance guide unit
Harness clamp
Bracket
Screw
Screw