EasyManua.ls Logo

Toshiba E-STUDIO520 - Jams at Small Original Exit Section; Jams at Intermediate Transport Section

Toshiba E-STUDIO520
466 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF) March 2005 © TOSHIBA TEC
16 - 40
16.6.5 Jams at small original exit section
1) Original jammed not reaching the small original exit sensor (S67) (from the intermediate transport
section side) : E728
- Jam detection
This jam is detected during the time after an original reaches the intermediate transport roller
until it reaches the small original exit sensor (S67).
- Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the intermediate transport roller to the small original exit sensor (S67)
plus 60 mm.
2) Original jammed at the small original exit sensor (S67) (from the intermediate transport section side)
: E732
- Jam detection
This jam is detected during the time after the deceleration, which is set to finish at the position 20
mm short of the small original exit sensor (S67), starts until an original passes through the small
original exit sensor (S67).
- Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an origi-
nal to proceed 60 mm.
3) Original jammed not reaching the small original exit sensor (from the small original reverse side) :
E743
- Jam detection
This jam is detected during the time after an original reaches the small original reverse sensor
(S66) until it reaches the small original exit sensor (S67).
- Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an origi-
nal to proceed 60 mm.
4) Original jammed at the small original exit sensor (S67) (from the small original reverse side) : E732
- Jam detection
This jam is detected during the time after the deceleration, which is set to finish at the position 20
mm short of the small original exit sensor (S67), starts until an original passes through the small
original exit sensor (S67).
- Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an origi-
nal to proceed 60 mm.
16.6.6 Jams at intermediate transport section
1) Original jammed not reaching the original intermediate transport sensor (S70) : E752
- Jam detection
This jam is detected during the time after an original reaches the 3rd roller until it reaches the
original intermediate transport sensor (S70).
- Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the 3rd roller to the original intermediate transport sensor (S70) plus
30 mm.

Table of Contents

Other manuals for Toshiba E-STUDIO520

Related product manuals