ADJUSTMENT
3 - 48
(4) Tighten the screw that temporarily screwed.
Note: Note:
In this step check the Mylar attached before
the separation roller because the roller life
may become shorter if this Mylar is scraped
and worn.
Reference value of distance C (from the
edge of the plate to that of the Mylar):
7.9±0.2 mm
* If the distance C is 7.0 mm or shorter, the
Mylar must be replaced.
Fig. 3-47
C
06/09